1 M High-voltage power supply system (touchscreen control)
1.1 M The positive pressure range is adjustable from DC 0 to +30kV, and the negative pressure range is adjustable from DC-30 to 0kV
1.2 M The current display accuracy is less than 0.001mA
1.3 M Overvoltage and overcurrent protection
1.4 M After enabling exception protection, the power supply will be shut down or delayed
1.5 M The rise time is 500ms to 2s
1.6 M You can set the number of times and time limit for abnormal protection and slow start
2 M Precision Liquid Supply System (Touchscreen Control)
2.1 M The number of independent channels is ≥2, and each channel can be independently controlled
2.2 M The flow range was 0.01ml / h ~ 999.99ml / h, and the control precision was ≤0.01ml / h
2.3 M The range of applicable syringes covers 10μL to 60mL
3 M Mobile System (Touchscreen Control)
3.1 M The X-axis and Z-axis must support manual adjustment to meet basic positioning requirements for distance, height, and angle
3.2 M Y axis (program control axis) movement range: 180mm
3.2 M The speed range of the Y axis is 0.01mm / s to 30 mm / s, and the speed accuracy is less than or equal to 0.01mm / s
3.4 M The Y axis is set to move reciprocally at a constant speed, and the reciprocating distance can be adjusted automatically
4 M Film Collection System (Touchscreen Control)
4.1 M Rotating type wire collector: speed range 0. 1-3000rpm, precision ≤0.1 rpm; type of rotating roller, rotating cage, rotating disc, ultra narrow rotating roller, rotating shaft, rotating plate.
4.11 M The size of the roller is 250mm in length and 89mm in diameter
4.12 M The cage size was 200mm in length and 115 mm in diameter
4.13 M Disc size: 5 mm thick, 115 mm in diameter, double disc
4.14 M Ultra-narrow roller dimensions: length 50mm, diameter 89mm
4.15 M Shaft dimensions: 2, 3, 4, 5, 6, 7, 8, 9, 10 mm in diameter, 9 models
4.2 M Flat panel (single control): Single effective receiving area: 200mm × 200mm
4.3 M Mesh crawler type (single control): width: 300mm, precision speed adjustment: 0. 1-300cm/ min, material:PTFE
4.4 M The effective receiving area of the single control plate was 300mm × 300mm
5 M Experimental Control System (Touchscreen Control)
5.1 M 7-inch full-color HD touchscreen,The control system has software patent
5.2 M The system has the function of experiment parameter database, which can store and call the historical experiment parameters with one key: 18 groups
6 M Environmental Control System (Touchscreen Control)
6.1 M The temperature control range was room temperature to 70℃, and the control precision was less than 0. 1℃
6.2 M The box is fully covered with anti-corrosion insulation material and the back panel is black
6.3 M Exhaust system: ultra-quiet five-stage adjustable exhaust system
6.4 M It features a visual design with three large high-perspective windows and high-brightness bidirectional lighting
6.5 M Ultraviolet sterilization function
6.6 M The air flow buffer valve can expand the dehumidification function
7 M Airflow Assist System
7.1 M High-precision air pump: Pressure range 0-100KPa, adjustment accuracy ≤0.2KPa, adjustable positive and negative pressure
7.2 M
Airflow controller: Pressure regulation range 0-0.9 MPa, adjustment accuracy ≤0.002 MPa, flow rate range
0. 1-100L/min, adjustable flow rate, with functions such as filtration and drying
7.3 M At least 3 sets of dedicated air jet nozzles, with outer needle specifications ranging from 0.15-0.2 mm and inner needle specifications from 18-27G-36 gauge
8 M Security System
8.1 M Multi-point safety grounding, one button pause, one button emergency stop, automatic power off when opening door
9 M Others
9.1 M The overall dimensions of the machine are ≤1000*700*1150mm (width*depth*height), with an internal dimension of ≥950*640*680mm
9.2 M The body shall be equipped with necessary movable pulleys and fixed columns